29 research outputs found

    Areas of Effectiveness of Half-Sine Monophasic and Biphasic Depolarizing Defibrillation Pulses on the Diagram of Energy / Phase of Fibrillation Cycle

    Full text link
    Благодарим АО «ПО «УОМЗ», в лице главного конструктора КБ медицинских изделий Чупова Алексея Александровича, за активное развитие прикладных исследований в области электрической дефибрилляции.Поступила: 15.12.2021. Принята в печать: 12.01.2022.We are grateful to JSC PA UOMZ, represented by the chief designer of the design bureau of medical devices, Aleksey A. Chupov, for the active development of applied research in the field of electrical defibrillation.Received: 15.12.2021. Accepted: 12.01.2022.Целью данного исследования является сравнение областей эффективности полусинусоидальных монополярного и биполярного деполяризующих дефибрилляционных импульсов на диаграмме энергия / фаза цикла фибрилляции. Результаты компьютерного моделирования показали, что области эффективности у монополярного и биполярного дефибрилляционных импульсов имеют существенное различие. У биполярного импульса доля цикла фибрилляции, на которой обеспечивается удлинение рефрактерности, при низких значениях энергии дефибрилляционного импульса существенно превышает таковую у монополярного импульса. Можно предположить, что этим обеспечивается энергетическое преимущество биполярного импульса дефибрилляции перед монополярным.The aim of this study is to compare the areas of effectiveness of half-sine monophasic and biphasic depolarizing defibrillation pulses in the diagram of energy / phase of fibrillation cycle. The study was carried out on the ten Tusscher-Panfilov 2006 model of the human ventricular myocyte under the influence of simulated fibrillation in the BeatBox simulation environment under the Fedora operating system. The simulation was carried out on a computer under the Windows 10 operating system, the Fedora operating system was implemented in the Oracle VM VirtualBox virtualization environment. The results of computer simulations have shown that the areas of effectiveness for monophasic and biphasic defibrillation pulses are significantly different. In a biphasic pulse, the fraction of a fibrillation cycle at which refractoriness is extended is significantly higher than that of a monophasic pulse at low defibrillation pulse energies. It can be assumed that this provides the energy advantage of a biphasic defibrillation pulse over a monophasic one.Настоящие исследования выполнены при реализации проекта «Создание высокотехнологичного производства медицинских изделий для восстановления функции сердца в обеспечение общедоступной дефибрилляции».This research was carried out during the implementation of the project “Creation of high-tech production of medical devices for the restoration of heart function to ensure public defibrillation”

    Испытания экспериментального образца носимого аппарата «искусственная почка »

    Get PDF
    Aim. The article presents the results of wearable artificial kidney (WAK) biomedical trial based on peritoneal dialysis with continuous dialysate regeneration.Materials and methods. The trial was carried out on a 15-kg dog. First stage: dialysis was carried out on healthy dog to evaluate effect of WAK on blood biochemical indicators. Second stage: 200 ml of X-ray contrast agent was injected into dog’s bloodstream to simulate acute kidney failure.Results. During trial (39.5 hours) WAK was performing continuous peritoneal dialysis with dialysis fluid regeneration. During second stage (34 hours) creatinine and uric acid were eliminated from dialysis solution at the rate of 0.3 mg/h, urea was eliminated at the rate of 0.15 g/h, total removed ultrafiltrate volume was 350 ml. At the end of the second stage blood biochemical indicators stabilised in the range of normal values.Conclusion. Developed WAK can perform continuous blood purification and ultrafiltration with no pathologic impact on blood biochemical indicators.Цель. В статье представлены результаты медико-биологических испытаний носимого аппарата «искусственная почка» на основе перитонеального диализа с постоянной регенерацией диализирующего раствора.Материалы и методы. Испытания проводились на собаке весом 15 кг. На первом этапе проводился диализ собаке с работающими почками для оценки влияния аппарата на биохимические параметры крови. На втором этапе собаке введено 200 мл рентгеноконтрастного вещества, для того чтобы вызвать острую почечную недостаточность.Результаты. В ходе испытаний аппарат производил непрерывный перитонеальный диализ с регенерацией диализного раствора в течение 39,5 часа. За время второго этапа (34 часа) из диализирующего раствора удалялся креатинин и мочевая кислота со скоростью 0,3 мг/ч и мочевина со скоростью 0,15 г/ч, общий объем удаленного ультрафильтрата составил 350 мл. По окончании второго этапа испытаний биохимические показатели крови стабилизировались до нормальных значений.Заключение. Разработанный аппарат позволяет производить искусственное очищение крови с ультрафильтрацией, не оказывая патологического воздействия на биохимические показатели крови

    Structures formed in unstable evaporation of cathodes in pulsed unipolar discharge in the gas

    No full text
    22.00; Translated from Russian (Fiz. Khim. Obrab. Mater. 1989 v. 23(1) p. 75-79)Available from British Library Document Supply Centre- DSC:9023.19(VR-Trans--4396)T / BLDSC - British Library Document Supply CentreSIGLEGBUnited Kingdo
    corecore